1 Hr Concrete Floor With Wood Framing And Gyp

Ul l522 1 2 12 7 mm fire shield c gypsum wallboard or 37 ngc 4042 32 66 ga fc 5410 1 2 12 7 mm fire shield c kal kore plaster base nail ngc 5032a.
1 hr concrete floor with wood framing and gyp. The first section of a wood framed ul design is a series of flooring system options i e. Can you pour 3 gypcrete 600 sq. Wood stud chase walls. Concrete with cellular steel 3 hr.
Gypsum wallboard floor ceilings wood framing wood joists cad file name golds dwg or golds dxf no. Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire rated ceiling assembly. Wood joists supporting 1 25 4 mm nominal wood sub and 1 25 4 mm nominal finish floor or 19 32 15 1 mm plywood finished floor with long edges t g and 15 32. Wood stud partitions with framing 16 o c.
Assembly hr description ul cad drawings. Urb concealed grid system and tile. Accucrete is ideal for all types of wood frame and concrete construction. Here you can find drawings for our ul fire rated floor assemblies and ul fire rated ceiling assemblies.
Pour a minimum 1 1 2 in. Rated steel column assemblies. We are trying to level a recessed floor house built in 1992 with concrete slab. Iic no carpet carpet pad 1 1 hr.
System 1 system 2 etc. Ss 110 1 hour partition to concrete slab. Pour a minimum. Area separation fire walls.
3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete. 38 mm of lightweight concrete 3. Multi family commercial and renovation projects. 12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr.
With 1 7 8 48 mm 6d nails 6 152 mm o c. This section provides three choices for meeting the minimum requirement for achieving a one hour fire rating. We were advised to use 3 of gypcrete to level the floors so consistent engineered wood floors can be laid. Half of the front of the house is recessed and the other half is all concrete with carpet on top.
276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr. Add a second layer of plywood 2. 5 8 15 9 mm toughrock fireguard x products applied perpendicular to 2 x 10 wood joists 16 406 mm o c. 2 hr 3 hr 2 hr 3 hr electrical penetrations through concrete over metal deck simplified drawing 8 25 15 1 hr 2 hr 1 hr 2 hr electrical penetrations through gypsum wall simplified drawing 8 25 15 dwg pdf cast in floor device for combustible penetrations comprehensive drawing 8 25 15 dwg pdf cast in floor device for non combustible.
Description stc test no. Approved for 1 and 2 hour ul fire ratings accucrete provides a smooth dense surface excellent for a variety of floor coverings from carpeting to hardwood.